Gary Smith

A Comprehensive Guide to Type B Vent Caps

B Vent Cap Guide


That little metal cap on the roof is the last part of a Type B gas vent. It gives combustion gases a place to discharge outdoors and helps keep rain and debris out of the pipe. If the cap is missing or damaged, the right replacement depends on the vent system and the appliance it serves.

Here’s how to tell what kind of cap you’re looking at, what matters when replacing one, and what you can look for from the ground.

Installation Manuals and Sources | Original Gemini Research


Types of Type B Vent Caps

A standard roof cap is the usual choice where the vent manufacturer lists it for the system. Some manufacturers also offer a high-wind cap for particular vent models and sizes. If wind seems to be affecting an appliance, have the vent layout and draft checked before assuming a different cap will solve the problem.

A universal cap can fit more than one vent model. The installation sheet tells you which ones. For example, the DuraVent Universal Gas Vent Cap instructions name specific models from DuraVent, Hart & Cooley, and Selkirk. Check both the model and the pipe diameter before choosing a replacement.

A tee cap closes an unused opening at a vent tee and can provide access for inspection or cleaning. The cap at the roof is a separate fitting that lets combustion gases discharge.

Which Appliances Use Type B Gas Vent?

You may find Type B gas vent on a natural gas or propane water heater, furnace, boiler, or some gas fireplaces. Start with the appliance model and its installation manual. Type B serves compatible Category I gas appliances, including many draft-hood-equipped models. Category II, III, and IV appliances require the venting specified by their manufacturer. A wood-burning appliance needs a chimney system approved for that use. See the Selkirk round and oval gas vent instructions.

The Cap, Flashing, and Storm Collar

From the ground, these parts can look like one assembly. The cap sits at the top of the pipe. The flashing seals the opening where the pipe passes through the roof, and the storm collar helps shed water over the flashing. If you see a ceiling stain near the vent, have the roof penetration and the vent checked so the source of the moisture can be identified.

Round and Oval Vent Pipe

Type B vent pipe comes in round and oval profiles. Some oval models are listed for installation in a framed wall, and the manufacturer may specify a transition to round pipe before the roof. Match the replacement cap to the vent at the termination. Vent sizing for the appliance is a separate question that depends on the appliance input, the vent height and layout, and whether other appliances share the vent.

What Type B Vent Pipe Is Made Of

Type B vent pipe is double-walled. One common construction uses an aluminum inner liner, a galvanized steel outer wall, and an insulating air space between them. That describes the pipe. Cap construction and temperature limits depend on the specific product. See the DuraVent Model BV specifications.

Keep the Vent Opening Clear

If a bird or other animal is getting into the vent, have a qualified technician check the cap and look for obstructions. Leave steel wool, makeshift screens, and other improvised materials out of the vent. They can restrict the opening that carries combustion gases outdoors.

How High Should the Cap Be Above the Roof?

Roof pitch, vent size, and nearby walls can all affect the required height. For example, the DuraVent Model BV instructions show a 12-inch minimum measured from the roof to the lowest discharge opening for certain installations on slopes up to 7:12. That example applies only when the vent meets the manual’s other conditions, including at least 8 feet from a vertical wall. The same manual gives a separate rule for larger terminations and those close to walls. Use the instructions for the actual vent system and check the locally adopted fuel gas code.

The pipe also needs the specified air space around combustible materials such as framing and roof sheathing. Many residential Type B systems call for at least 1 inch, but the product label and installation instructions give the clearance for that model. Keep that air space free of insulation. UL 441 is a product standard for gas vents. The product listing, manufacturer’s instructions, and local code govern the installation.

What You Can Look For From the Ground

Look for a missing or tilted cap, obvious damage, heavy corrosion, or debris around the opening. A ground-level view can help you spot a visible problem. A closer inspection is needed to check the cap’s attachment, concealed clearances, and whether the appliance is venting properly.

Choosing the Right Replacement Cap

If the cap is missing, loose, or damaged, ask a qualified HVAC or gas-appliance technician to identify the vent make, model, and diameter, select a cap listed for that combination, and check the rest of the vent. A cap that fits over the pipe may still be the wrong part.

Check the Warranty for the Cap

Cap coverage can differ from coverage for the rest of the vent. For DuraVent Model BV, the manufacturer’s manual includes a separate warranty provision for termination caps. Check the terms for your exact product and purchase.

If the Carbon Monoxide Alarm Sounds

Get everyone outside into fresh air, call 911 from outside, and wait for emergency responders to say it’s safe to go back in. The U.S. Consumer Product Safety Commission’s carbon monoxide fact sheet explains what to do.